Page 1 - TRIPLETT MODEL 1101-A

TRIPLETT MODEL 1101-A 1

Page 2 - CONTENTS

Note: a) The following accuracy specifications are valid at 23 degrees C, +/- 5 degrees C, Relative Humidity less than 75% b) The specifications

Page 3

Resistance Range Resolution Accuracy 200Ω 0.1Ω ± (0.8% rdg + 5 digits) 2000Ω 1Ω 20KΩ 10Ω 200KΩ 100Ω ± (0.8% rdg + 2 digits) 20MΩ 10KΩ ± (1.0% rdg +

Page 4

6: FRONT PANEL 1) Backlit LCD Display 2) Backlight and Hold button 3) Rotary Function / Range Selector Switch 4) Transistor Test Jack

Page 5

7.1 DC Voltage Measurement: 7: MEASUREMENT PROCEDURES WARNING!If the magnitude of the voltage to be measured is unknown, always st

Page 6 - 3: INTERNATIONAL SYMBOLS

probes, and rotate the RANGE switch to the next lower position. Reconnect the test probes, reapply power, and read the voltage on the LCD display. If

Page 7 - ~ AC: Alternating Current

7.2.5 If the displayed value is less than "200" (decimal point not shown), a more accurate reading may be obtained by setting the RANGE sw

Page 8 - 4: PRODUCT FEATURES

measure 10A, the current being tested exceeds the measurement capability of the meter and cannot be measured. 7.3.5 If the displayed value is less t

Page 9 - 5: SPECIFICATIONS

7.5 Continuity Beeper: WARNING! Do not apply voltage or current to the meter when it is set to the Diode Test / Continuity Beeper mode .

Page 10

are connected in either direction to the diode, the diode is probably shorted. Note: The reading displayed on the LCD is not an accurate indication o

Page 11 - Can measure NPN or PNP

8: BACKLIGHT AND HOLD 8.1 Backlight: The 1101-A incorporates a light green LED backlight into the LCD assembly. Since the backlight uses mo

Page 12 - FRONT PANEL

COMPACT, DIGITAL MULTIMETER WITH BACKLIT DISPLAY & TEMPERATURE TEST 2 1. Introduction 2. Safety Rules and Warnings 3. International Symbols 4.

Page 13 - WARNING!

9: MAINTENANCE 9.1 Battery and Fuse Replacement: 9.1.1 On the back of the case, remove the rubber bumpers that cover the case screws. Re

Page 14

21Note: When replacing the fuse, use the exact type specified. Do not substitute a 250V fuse for the 500V fuse. 9.2 Cleaning: To clean th

Page 15

10: TRIPLETT THREE YEAR LIMITED WARRANTY The Triplett Corporation warrants instruments and test equipment manufactured by it to be free from defec

Page 16

23Some states (USA ONLY) do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may no

Page 18

WARNING!!! This meter is NOT to be used to measure High Energy circuits (power circuitry fused at greater than 4KW, such as di

Page 19 - 8: BACKLIGHT AND HOLD

2.13 Insert the test leads in the jacks specified in the instructions for performing particular tests. Inserting the test leads in incorrect jacks c

Page 20 - 9: MAINTENANCE

5conditions. Allow the meter to warm to room temperature before using. 2.28 Do not modify the meter. Changing the design may make the meter unsafe

Page 21

2.40 Do not use the meter if it does not appear to work correctly on all ranges and in all modes. 2.41 Do not use the meter if it has undergone long

Page 22 - 10: TRIPLETT THREE YEAR

The following International Symbols are used throughout this manual and on the case of the meter to identify, caution, or warn the user of important

Page 23

4: PRODUCT FEATURES 4.1 20 Measurement Ranges 4.2 0.5" (12mm) high LCD display 4.3 3 1/2 digit resolution (2000 counts) 4.4 Backlit LCD di

Page 24

9 5.1 Display: ......... 0.5" (12mm) high LCD 5.2 Display Resolution: .... 2000 counts, 0000 to 1999 5.3 Ove